Flow Battery Reproducibility Study – Participant 41 (Phase 2b)
Description
Submission from participant 41 as part of the Flow Battery Reproducibility Study, Phase 2b. Job role: Government researcher. Experience: 5–10 years.
Additional details
Domain Specific Metadata
| Property | Value |
|---|---|
| Fb Data Collection Phase | Phase 2b |
| Fb Job Role | Government researcher |
| Fb Experience Flow Batteries | 5–10 years |
| Fb Participant Identifier | 41 |
| Fb Number Of Repeats | 3 |
| Fb Electrode Pretreatment Type | Heat-treated |
| Fb Heat Treatment Furnace Type | Muffle |
| Fb Heat Treatment Atmosphere | Air |
| Fb Heat Treatment Ramp Rate | 3.125 |
| Fb Heat Treatment Dwell Temperature | 400.0 |
| Fb Heat Treatment Dwell Time | 24.0 |
| Fb Heat Treatment Cooling Method | Passive |
| Fb Heat Treatment Batching | Single batch |
| Fb Time Between Heat Treatment And Use | 20.0 |
| Fb Electrode Storage After Heat Treatment | Enclosed (non-inert) |
| Fb Electrode Storage After Receipt | Open to air |
| Fb Membrane Storage Type | Wet |
| Fb Membrane Storage Liquid | 1 M KCl aqueous solution |
| Fb Membrane Storage Details | Stored in a transparent, colorless glassy bottle. |
| Fb Membrane Pretreatment | No (used as received) |
| Fb Ferrocyanide Chemical Details | Potassium hexacyanoferrate(II) trihydrate, K4Fe(CN)6 · 3H2O |
| Fb Ferrocyanide Purity | 99.95 |
| Fb Ferrocyanide Supplier | Sigma Aldrich |
| Fb Ferricyanide Chemical Identity | Potassium ferricyanide(III), K3Fe(CN)6 |
| Fb Ferricyanide Purity | 99.0 |
| Fb Ferricyanide Supplier | Sigma Aldrich |
| Fb Supporting Electrolyte Identity | Potassium chloride, KCl |
| Fb Potassium Chloride Purity | 99.0 |
| Fb Potassium Chloride Supplier | Fisher Chemical |
| Fb Water Type | Deionised |
| Fb Water Purification System | Aqua Solutions |
| Fb Water Purification Details | Model number: 2122A. |
| Fb Water Resistivity | 18.2 |
| Fb Electrolyte Preparation Strategy | The same electrolyte in repeat #1 and #2. Prepared another 100 mL and mixed with the leftover for repeat #3. |
| Fb Electrolyte Batch Size | 1000.0 |
| Fb Electrolyte Storage Environment | Dark (cupboard/covered) |
| Fb Electrolyte Storage Duration | 816.0 |
| Fb Electrolyte Volume Measurement Method | Volumetric |
| Fb Reagent Purity Used | Yes |
| Fb Water Ph Measured | No |
| Fb Electrolyte Ph Measured | Yes |
| Fb Electrode Cutting Method | Manual cutting using ruler and razor/scalpel |
| Fb Potentiostat Usage | Single instrument for all tests |
| Fb Potentiostat Manufacturer Cycling | Biologic |
| Fb Potentiostat Model Cycling | Biologic VSP with a Biologic VMP3B-20 amplifier. |
| Fb Potentiostat Manufacturer Polarisation | Biologic |
| Fb Potentiostat Model Polarisation | Biologic VSP with a Biologic VMP3B-20 amplifier. |
| Fb Potentiostat Manufacturer Impedance | Biologic |
| Fb Potentiostat Model Impedance | Biologic VSP with a Biologic VMP3B-20 amplifier. |
| Fb Potentiostat Calibration Frequency | Calibrated only when issues arise |
| Fb Potentiostat Calibration Method | Dummy cell (manufacturer supplied) |
| Fb Connection Method | Crocodile/alligator clips |
| Fb Electrical Connection Scheme | 2-point (2-wire) |
| Fb Potentiostat Cable Length | 1–2 m |
| Fb Potentiostat Cable Type | Manufacturer cable – standard length |
| Fb Potentiostat Cable Shielding | Shielded |
| Fb Number Of Pumps | Single (including dual head) |
| Fb Pump Type | Peristaltic |
| Fb Pump Manufacturer | Masterflex (Cole-Parmer/Avantor) |
| Fb Pump Model | Masterflex 7557-04 controller, Masterflex 7557-02 pump drive, Masterflex 77202-60 pump head. |
| Fb Reservoir Material | Glass (borosilicate) |
| Fb Reservoir Type | Duran/Schott bottle (GL bottle) |
| Fb Reservoir Volume | 100.0 |
| Fb Electrolyte Volume Used | 100 |
| Fb Impedance Reservoir Config | Double reservoir |
| Fb Polarisation Reservoir Config | Single reservoir |
| Fb Temperature Control | Ambient (not controlled) |
| Fb Laboratory Temperature | 22–24 °C |
| Fb Pump Flow Rate Calibrated | Yes |
| Fb Calibration With Cell | Yes |
| Fb Calibration Fluid | Electrolye |
| Fb Pump Recalibrated | No |
| Fb Pump Calibration Method | Manual volumetric |
| Fb Leak Test Performed | Yes |
| Fb Break In Performed | Yes |
| Fb Break In Duration | 1.0 |
| Fb Break In Flow Rate | 25 |
| Fb Cell Assembly Issues | The alignment of the cell jig with back plates is not very good. Two bolts threads got damaged because they got bended by the back plates. |
| Fb Additional Experiments | Yes |
| Fb Repeat Method | Full cell disassembly and rebuild, fresh electrolyte |
| Fb Electrolyte Leakage Reported | No |
| Fb Typical Group Practice Leaks | Tolerate minor leaks (documentation/reporting unnecessary) |
| Fb Electrolyte Stirring | No |
| Fb Electrolyte Sparging | No |
| Fb Polarisation Beyond Limits | No |
| Fb Impedance Control Mode | Potentiostatic (PEIS) |
| Fb Consent Public Display | Yes |