Flow Battery Reproducibility Study – Participant 01 (Phase 2b)

  • 1. STFC

Description

Submission from participant 01 as part of the Flow Battery Reproducibility Study, Phase 2b. Job role: Industry researcher. Experience: 5–10 years.

Additional details

Domain Specific Metadata

 
Property Value
Fb Data Collection Phase Phase 2b
Fb Job Role Industry researcher
Fb Experience Flow Batteries 5–10 years
Fb Participant Identifier 01
Fb Number Of Repeats 3
Fb Electrode Pretreatment Type Heat-treated
Fb Heat Treatment Furnace Type Muffle
Fb Heat Treatment Atmosphere Air
Fb Heat Treatment Ramp Rate 6.0
Fb Heat Treatment Dwell Temperature 400.0
Fb Heat Treatment Dwell Time 24.0
Fb Heat Treatment Cooling Method Passive
Fb Heat Treatment Batching Single batch
Fb Time Between Heat Treatment And Use 1.0
Fb Electrode Storage After Heat Treatment Enclosed (non-inert)
Fb Electrode Storage After Receipt Enclosed (non-inert)
Fb Membrane Storage Type Wet
Fb Membrane Storage Liquid The water in the vials the membrane was shipped in with some refills with ultrapure water
Fb Membrane Storage Details Stored in the container included with test kit
Fb Membrane Pretreatment No (used as received)
Fb Ferrocyanide Chemical Details Potassium hexacyanoferrate(II) trihydrate, K4Fe(CN)6 · 3H2O
Fb Ferrocyanide Purity 98.5
Fb Ferrocyanide Supplier Merck
Fb Ferricyanide Chemical Identity Potassium ferricyanide(III), K3Fe(CN)6
Fb Ferricyanide Purity 99.0
Fb Ferricyanide Supplier Merck
Fb Supporting Electrolyte Identity Potassium chloride, KCl
Fb Potassium Chloride Purity 99.0
Fb Potassium Chloride Supplier Merck
Fb Water Type Ultrapure
Fb Electrolyte Preparation Strategy For each repeat 3 100 ml solutions were prepared separately the day before
Fb Electrolyte Batch Size 100.0
Fb Electrolyte Storage Environment Dark (cupboard/covered)
Fb Electrolyte Storage Duration 24.0
Fb Electrolyte Volume Measurement Method Volumetric
Fb Reagent Purity Used No
Fb Water Ph Measured No
Fb Electrolyte Ph Measured No
Fb Electrode Cutting Method Manual cutting using ruler and razor/scalpel
Fb Potentiostat Usage Single instrument for all tests
Fb Potentiostat Manufacturer Cycling Biologic
Fb Potentiostat Model Cycling VSP-3e
Fb Potentiostat Manufacturer Polarisation Biologic
Fb Potentiostat Model Polarisation VSP-3e
Fb Potentiostat Manufacturer Impedance Biologic
Fb Potentiostat Model Impedance VSP-3e
Fb Potentiostat Calibration Frequency Calibrated only when issues arise
Fb Potentiostat Calibration Method Manufacturer service
Fb Connection Method Crocodile/alligator clips
Fb Electrical Connection Scheme 2-point (4-wire)
Fb Potentiostat Cable Length 1–2 m
Fb Potentiostat Cable Type Manufacturer cable – standard length
Fb Potentiostat Cable Shielding Shielded
Fb Number Of Pumps Single (including dual head)
Fb Pump Type Peristaltic
Fb Pump Manufacturer Lead Fluid
Fb Pump Model BT600L
Fb Reservoir Material Glass (borosilicate)
Fb Reservoir Type Duran/Schott bottle (GL bottle)
Fb Reservoir Volume 110.0
Fb Electrolyte Volume Used 100
Fb Impedance Reservoir Config Single reservoir
Fb Polarisation Reservoir Config Single reservoir
Fb Temperature Control Ambient (not controlled)
Fb Laboratory Temperature 18–20 °C
Fb Pump Flow Rate Calibrated Yes
Fb Calibration With Cell No
Fb Calibration Fluid Water
Fb Pump Recalibrated No
Fb Pump Calibration Method Manual volumetric
Fb Leak Test Performed Yes
Fb Break In Performed Yes
Fb Break In Duration 4.0
Fb Break In Flow Rate 25
Fb Cell Assembly Issues After the first assembly, placing the first half-cell into the cell jig was harder, like the jig bended providing higher resistance.
Fb Additional Experiments Yes
Fb Repeat Method Cell and electrolyte unchanged (software-only rerun)
Fb Electrolyte Leakage Reported Yes
Fb Typical Group Practice Leaks Tolerate minor leaks but document/report
Fb Electrolyte Stirring No
Fb Electrolyte Sparging Yes
Fb Sparging Gas Argon
Fb Gas Humidification Not humidified
Fb Sparging Application Pre-sparge then headspace blanket
Fb Sparging Gas Flow Rate Not recorded
Fb Polarisation Beyond Limits No
Fb Impedance Control Mode Galvanostatic (GEIS)
Fb Consent Public Display Yes