Flow Battery Reproducibility Study – Participant 24 (Phase 2b)

  • 1. STFC

Description

Submission from participant 24 as part of the Flow Battery Reproducibility Study, Phase 2b. Job role: Postgrad/PhD student. Experience: 2–5 years.

Additional details

Domain Specific Metadata

 
Property Value
Fb Data Collection Phase Phase 2b
Fb Job Role Postgrad/PhD student
Fb Experience Flow Batteries 2–5 years
Fb Participant Identifier 24
Fb Number Of Repeats 3
Fb Electrode Pretreatment Type Heat-treated
Fb Heat Treatment Furnace Type Muffle
Fb Heat Treatment Atmosphere Air
Fb Heat Treatment Ramp Rate 100.0
Fb Heat Treatment Dwell Temperature 400.0
Fb Heat Treatment Dwell Time 24.0
Fb Heat Treatment Cooling Method Passive
Fb Heat Treatment Batching Treated individually before each test
Fb Time Between Heat Treatment And Use 6.0
Fb Electrode Storage After Heat Treatment Open to air
Fb Electrode Storage After Receipt Enclosed (non-inert)
Fb Membrane Storage Type Wet
Fb Membrane Storage Liquid distilled H2O
Fb Membrane Storage Details Stored in the falckon in which it was send
Fb Membrane Pretreatment No (used as received)
Fb Ferrocyanide Chemical Details Potassium hexacyanoferrate(II) trihydrate, K4Fe(CN)6 · 3H2O
Fb Ferrocyanide Purity 98.0
Fb Ferrocyanide Supplier Thermo Scientific
Fb Ferricyanide Chemical Identity Potassium ferricyanide(III), K3Fe(CN)6
Fb Ferricyanide Purity 98.0
Fb Ferricyanide Supplier Thermo Scientific
Fb Supporting Electrolyte Identity Potassium chloride, KCl
Fb Potassium Chloride Purity 100.0
Fb Potassium Chloride Supplier Supelco
Fb Water Type Distilled
Fb Electrolyte Preparation Strategy Freshly prepared for each experiment
Fb Electrolyte Batch Size 100.0
Fb Electrolyte Storage Environment Ambient lab light
Fb Electrolyte Storage Duration 1.0
Fb Electrolyte Volume Measurement Method Volumetric
Fb Reagent Purity Used Yes
Fb Water Ph Measured No
Fb Electrolyte Ph Measured No
Fb Electrode Cutting Method Manual cutting using ruler and razor/scalpel
Fb Potentiostat Usage Different instruments for some/all tests
Fb Potentiostat Manufacturer Cycling Neware
Fb Potentiostat Model Cycling BTS4000
Fb Potentiostat Manufacturer Polarisation Metrohm Autolab
Fb Potentiostat Model Polarisation PGSTAT302N
Fb Potentiostat Manufacturer Impedance Metrohm Autolab
Fb Potentiostat Model Impedance PGSTAT302N
Fb Potentiostat Calibration Frequency Unknown
Fb Connection Method Crocodile/alligator clips
Fb Electrical Connection Scheme 4-point (4-wire)
Fb Potentiostat Cable Length 2–3 m
Fb Potentiostat Cable Type Manufacturer cable – standard length
Fb Potentiostat Cable Shielding Shielded
Fb Number Of Pumps Single (including dual head)
Fb Pump Type Peristaltic
Fb Pump Manufacturer Masterflex (Cole-Parmer/Avantor)
Fb Pump Model Masterflex L/S Digital Drive
Fb Reservoir Material Glass (borosilicate)
Fb Reservoir Type Duran/Schott bottle (GL bottle)
Fb Reservoir Volume 250.0
Fb Electrolyte Volume Used 100
Fb Impedance Reservoir Config Single reservoir
Fb Polarisation Reservoir Config Single reservoir
Fb Temperature Control Ambient (not controlled)
Fb Laboratory Temperature 18–20 °C
Fb Pump Flow Rate Calibrated No
Fb Leak Test Performed Yes
Fb Break In Performed Yes
Fb Break In Duration 1.0
Fb Break In Flow Rate 25
Fb Cell Assembly Issues No
Fb Additional Experiments No
Fb Electrolyte Leakage Reported No
Fb Typical Group Practice Leaks Discard data if any leak occurs | Case-by-case decision | other (please specify)
Fb Electrolyte Stirring No
Fb Electrolyte Sparging No
Fb Polarisation Beyond Limits No
Fb Impedance Control Mode Potentiostatic (PEIS)
Fb Consent Public Display Yes