Flow Battery Reproducibility Study – Participant 33 (Phase 2b)
Description
Submission from participant 33 as part of the Flow Battery Reproducibility Study, Phase 2b. Job role: Postgrad/PhD student. Experience: < 6 months.
Additional details
Domain Specific Metadata
| Property | Value |
|---|---|
| Fb Data Collection Phase | Phase 2b |
| Fb Job Role | Postgrad/PhD student |
| Fb Experience Flow Batteries | < 6 months |
| Fb Participant Identifier | 33 |
| Fb Number Of Repeats | 3 |
| Fb Electrode Pretreatment Type | None |
| Fb Electrode Storage After Receipt | Enclosed (non-inert) |
| Fb Membrane Storage Type | Wet |
| Fb Membrane Storage Liquid | UltraPure Water |
| Fb Membrane Storage Details | Stored in a glass container |
| Fb Membrane Pretreatment | No (used as received) |
| Fb Ferrocyanide Chemical Details | Potassium hexacyanoferrate(II) trihydrate, K4Fe(CN)6 · 3H2O |
| Fb Ferrocyanide Purity | 98.5 |
| Fb Ferrocyanide Supplier | Sigma Aldrich |
| Fb Ferricyanide Chemical Identity | Potassium ferricyanide(III), K3Fe(CN)6 |
| Fb Ferricyanide Purity | 99.0 |
| Fb Ferricyanide Supplier | Sigma Aldrich |
| Fb Supporting Electrolyte Identity | Potassium chloride, KCl |
| Fb Potassium Chloride Purity | 99.0 |
| Fb Potassium Chloride Supplier | Sigma Aldrich |
| Fb Water Type | UltraPure |
| Fb Electrolyte Preparation Strategy | One batch per repeat |
| Fb Electrolyte Batch Size | 500.0 |
| Fb Electrolyte Storage Environment | Ambient lab light |
| Fb Electrolyte Storage Duration | 24.0 |
| Fb Electrolyte Volume Measurement Method | Volumetric |
| Fb Reagent Purity Used | No |
| Fb Water Ph Measured | No |
| Fb Electrolyte Ph Measured | Yes |
| Fb Electrode Cutting Method | Template-guided manual cutting |
| Fb Potentiostat Usage | Single instrument for all tests |
| Fb Potentiostat Manufacturer Cycling | Ivium |
| Fb Potentiostat Model Cycling | Ivium-n-Stat |
| Fb Potentiostat Manufacturer Polarisation | Ivium |
| Fb Potentiostat Model Polarisation | Ivium-n-Stat |
| Fb Potentiostat Manufacturer Impedance | Ivium |
| Fb Potentiostat Model Impedance | Ivium-n-Stat |
| Fb Potentiostat Calibration Frequency | Less frequently than yearly |
| Fb Potentiostat Calibration Method | Dummy cell (manufacturer supplied) |
| Fb Connection Method | Crocodile/alligator clips |
| Fb Electrical Connection Scheme | 2-point (4-wire) |
| Fb Potentiostat Cable Length | 1–2 m |
| Fb Potentiostat Cable Type | Manufacturer cable – standard length |
| Fb Potentiostat Cable Shielding | Shielded |
| Fb Number Of Pumps | Two separate pump |
| Fb Pump Type | Peristaltic |
| Fb Pump Manufacturer | Masterflex (Cole-Parmer/Avantor) |
| Fb Pump Model | Masterflex L/S Digital Drive |
| Fb Reservoir Material | Glass (borosilicate) |
| Fb Reservoir Type | Duran/Schott bottle (GL bottle) |
| Fb Reservoir Volume | 250.0 |
| Fb Electrolyte Volume Used | 100 |
| Fb Impedance Reservoir Config | Single reservoir |
| Fb Polarisation Reservoir Config | Single reservoir |
| Fb Temperature Control | Ambient (not controlled) |
| Fb Laboratory Temperature | 22–24 °C |
| Fb Pump Flow Rate Calibrated | Yes |
| Fb Calibration With Cell | Yes |
| Fb Calibration Fluid | Water |
| Fb Pump Recalibrated | No |
| Fb Pump Calibration Method | Manual volumetric |
| Fb Leak Test Performed | No |
| Fb Break In Performed | Yes |
| Fb Break In Duration | 0.5 |
| Fb Break In Flow Rate | 25 |
| Fb Cell Assembly Issues | No |
| Fb Additional Experiments | Yes |
| Fb Repeat Method | Full cell disassembly and rebuild, fresh electrolyte |
| Fb Electrolyte Leakage Reported | No |
| Fb Typical Group Practice Leaks | Case-by-case decision | other (please specify) |
| Fb Electrolyte Stirring | Yes |
| Fb Reservoir Stirring Method | Magnetic stir bar |
| Fb Stirring Rate | 600–1000 RPM |
| Fb Electrolyte Sparging | No |
| Fb Polarisation Beyond Limits | No |
| Fb Impedance Control Mode | Potentiostatic (PEIS) |
| Fb Consent Public Display | Yes |