Published August 2, 2026 | Version v1
Dataset

Flow Battery Reproducibility Study – Participant 09 (Phase 2b)

  • 1. STFC

Description

Submission from participant 09 as part of the Flow Battery Reproducibility Study, Phase 2b. Job role: Postgrad/PhD student. Experience: 2–5 years.

Additional details

Domain Specific Metadata

 
Property Value
Fb Data Collection Phase Phase 2b
Fb Job Role Postgrad/PhD student
Fb Experience Flow Batteries 2–5 years
Fb Participant Identifier 09
Fb Number Of Repeats 1
Fb Electrode Pretreatment Type None
Fb Electrode Storage After Receipt Enclosed (non-inert)
Fb Membrane Storage Type Wet
Fb Membrane Storage Liquid deionised H2O
Fb Membrane Pretreatment No (used as received)
Fb Ferrocyanide Chemical Details Potassium hexacyanoferrate(II) trihydrate, K4Fe(CN)6 · 3H2O
Fb Ferrocyanide Purity 99.0
Fb Ferrocyanide Supplier Roth
Fb Ferricyanide Chemical Identity Potassium ferricyanide(III), K3Fe(CN)6
Fb Ferricyanide Purity 99.0
Fb Ferricyanide Supplier Merck
Fb Supporting Electrolyte Identity Potassium chloride, KCl
Fb Potassium Chloride Purity 99.5
Fb Potassium Chloride Supplier Roth
Fb Water Type Deionised
Fb Water Purification System Unknown
Fb Water Purification Details Unknown
Fb Electrolyte Preparation Strategy Single stock batch used across repeats
Fb Electrolyte Batch Size 1000.0
Fb Electrolyte Storage Environment Ambient lab light
Fb Electrolyte Storage Duration 48.0
Fb Electrolyte Volume Measurement Method Volumetric
Fb Reagent Purity Used No
Fb Water Ph Measured No
Fb Electrolyte Ph Measured No
Fb Electrode Cutting Method Freehand manual cutting (approximate fit), razor/scalpel
Fb Potentiostat Usage Single instrument for all tests
Fb Potentiostat Manufacturer Cycling Gamry
Fb Potentiostat Model Cycling Reference 3000
Fb Potentiostat Manufacturer Polarisation Gamry
Fb Potentiostat Model Polarisation Reference 3000
Fb Potentiostat Manufacturer Impedance Gamry
Fb Potentiostat Model Impedance Reference 3000
Fb Potentiostat Calibration Frequency Calibrated only when issues arise
Fb Potentiostat Calibration Method Dummy cell (manufacturer supplied)
Fb Connection Method Bolted/screw connection
Fb Electrical Connection Scheme 2-point (4-wire)
Fb Potentiostat Cable Length 1–2 m
Fb Potentiostat Cable Type Manufacturer cable – extended length
Fb Potentiostat Cable Shielding Shielded
Fb Number Of Pumps Two separate pump
Fb Pump Type Diaphragm
Fb Pump Manufacturer ProMinent
Fb Pump Model ProMinent Delta OptoDrive
Fb Reservoir Material Glass (borosilicate)
Fb Reservoir Type Duran/Schott bottle (GL bottle)
Fb Reservoir Volume 250.0
Fb Impedance Reservoir Config Double reservoir
Fb Polarisation Reservoir Config Double reservoir
Fb Temperature Control Ambient (not controlled)
Fb Laboratory Temperature 20–22 °C
Fb Pump Flow Rate Calibrated Yes
Fb Calibration With Cell No
Fb Calibration Fluid Water
Fb Pump Recalibrated No
Fb Pump Calibration Method Calibration curve (RPM vs. flow rate)
Fb Leak Test Performed No
Fb Break In Performed No
Fb Cell Assembly Issues Assembly would in general be easier with an assembly rack. Cutting of the felts is a bit complicated due to the rounded edges. Positioning of membrane is a bit inconvenient - probably easier with a membrane cut to the dimensions of the gaskets with holes for the bolts.
Fb Additional Experiments No
Fb Electrolyte Leakage Reported Yes
Fb Typical Group Practice Leaks Tolerate minor leaks but document/report
Fb Electrolyte Stirring Yes
Fb Reservoir Stirring Method Magnetic stir bar
Fb Stirring Rate Not recorded
Fb Electrolyte Sparging No
Fb Polarisation Beyond Limits No
Fb Impedance Control Mode Potentiostatic (PEIS)
Fb Consent Public Display Yes