Published August 2, 2026 | Version v1
Dataset

Flow Battery Reproducibility Study – Participant 19 (Phase 2b)

  • 1. STFC

Description

Submission from participant 19 as part of the Flow Battery Reproducibility Study, Phase 2b. Job role: Postgrad/PhD student. Experience: 1–2 years.

Additional details

Domain Specific Metadata

 
Property Value
Fb Data Collection Phase Phase 2b
Fb Job Role Postgrad/PhD student
Fb Experience Flow Batteries 1–2 years
Fb Participant Identifier 19
Fb Number Of Repeats 4
Fb Electrode Pretreatment Type Heat-treated
Fb Heat Treatment Furnace Type Muffle
Fb Heat Treatment Atmosphere Air
Fb Heat Treatment Ramp Rate 0.0
Fb Heat Treatment Dwell Temperature 400.0
Fb Heat Treatment Dwell Time 24.0
Fb Heat Treatment Cooling Method Passive
Fb Heat Treatment Batching Treated individually before each test
Fb Time Between Heat Treatment And Use 10.0
Fb Electrode Storage After Heat Treatment Open to air
Fb Electrode Storage After Receipt Open to air
Fb Membrane Storage Type Dry
Fb Membrane Pretreatment No (used as received)
Fb Ferrocyanide Chemical Details Potassium hexacyanoferrate(II) trihydrate, K4Fe(CN)6 · 3H2O
Fb Ferrocyanide Purity 98.5
Fb Ferrocyanide Supplier Sigma Aldrich
Fb Ferricyanide Chemical Identity Potassium ferricyanide(III), K3Fe(CN)6
Fb Ferricyanide Purity 99.0
Fb Ferricyanide Supplier Sigma Aldrich
Fb Supporting Electrolyte Identity Potassium chloride, KCl
Fb Potassium Chloride Purity 100.0
Fb Potassium Chloride Supplier VVR Chemicals
Fb Water Type Deionised
Fb Water Purification System Unknown
Fb Water Purification Details Unknown
Fb Electrolyte Preparation Strategy One batch per repeat
Fb Electrolyte Batch Size 100.0
Fb Electrolyte Storage Environment Ambient lab light
Fb Electrolyte Storage Duration 1.0
Fb Electrolyte Volume Measurement Method Volumetric
Fb Reagent Purity Used No
Fb Water Ph Measured No
Fb Electrolyte Ph Measured No
Fb Electrode Cutting Method Manual cutting using ruler and razor/scalpel
Fb Potentiostat Usage Single instrument for all tests
Fb Potentiostat Manufacturer Cycling Gamry
Fb Potentiostat Model Cycling Interface 1010E
Fb Potentiostat Manufacturer Polarisation Gamry
Fb Potentiostat Model Polarisation Interface 1010E
Fb Potentiostat Manufacturer Impedance Gamry
Fb Potentiostat Model Impedance Interface 1010E
Fb Potentiostat Calibration Frequency Yearly
Fb Potentiostat Calibration Method Dummy cell (manufacturer supplied)
Fb Connection Method Crocodile/alligator clips
Fb Potentiostat Cable Length <1 m
Fb Potentiostat Cable Type Manufacturer cable – standard length
Fb Potentiostat Cable Shielding Unknown
Fb Number Of Pumps Single (including dual head)
Fb Pump Type Peristaltic
Fb Pump Manufacturer Masterflex (Cole-Parmer/Avantor)
Fb Pump Model Masterflex L/S Digital Drive
Fb Reservoir Material Glass (borosilicate)
Fb Reservoir Type Duran/Schott bottle (GL bottle)
Fb Reservoir Volume 120.0
Fb Electrolyte Volume Used 100
Fb Impedance Reservoir Config Single reservoir
Fb Polarisation Reservoir Config Single reservoir
Fb Temperature Control Ambient (not controlled)
Fb Laboratory Temperature 22–24 °C
Fb Pump Flow Rate Calibrated Yes
Fb Calibration With Cell Yes
Fb Calibration Fluid Water
Fb Pump Recalibrated Yes
Fb Pump Calibration Method Manual volumetric
Fb Leak Test Performed No
Fb Break In Performed Yes
Fb Break In Duration 2.0
Fb Break In Flow Rate 25
Fb Cell Assembly Issues No
Fb Additional Experiments Yes
Fb Repeat Method Full cell disassembly and rebuild, fresh electrolyte
Fb Electrolyte Leakage Reported No
Fb Typical Group Practice Leaks Tolerate minor leaks (documentation/reporting unnecessary)
Fb Electrolyte Stirring No
Fb Electrolyte Sparging Yes
Fb Sparging Gas Nitrogen
Fb Gas Humidification Not humidified
Fb Sparging Application Pre-sparge only
Fb Sparging Gas Flow Rate Not recorded
Fb Polarisation Beyond Limits No
Fb Impedance Control Mode Galvanostatic (GEIS)
Fb Consent Public Display Yes