Published August 2, 2026 | Version v1
Dataset

Flow Battery Reproducibility Study – Participant 05 (Phase 2b)

  • 1. STFC

Description

Submission from participant 05 as part of the Flow Battery Reproducibility Study, Phase 2b. Job role: Postgrad/PhD student. Experience: 6–12 months.

Additional details

Domain Specific Metadata

 
Property Value
Fb Data Collection Phase Phase 2b
Fb Job Role Postgrad/PhD student
Fb Experience Flow Batteries 6–12 months
Fb Participant Identifier 05
Fb Number Of Repeats 3
Fb Electrode Pretreatment Type Heat-treated
Fb Heat Treatment Furnace Type Muffle
Fb Heat Treatment Atmosphere Air
Fb Heat Treatment Ramp Rate 6.0
Fb Heat Treatment Dwell Temperature 400.0
Fb Heat Treatment Dwell Time 24.0
Fb Heat Treatment Cooling Method Passive
Fb Heat Treatment Cooling Details After 24 h the dish containing the electrodes was removed from the oven and cooled down under ambient conditions
Fb Heat Treatment Batching Single batch
Fb Time Between Heat Treatment And Use 6.0
Fb Electrode Storage After Heat Treatment Inert atmosphere
Fb Electrode Storage After Receipt Enclosed (non-inert)
Fb Membrane Storage Type Wet
Fb Membrane Storage Liquid Water that was shipped with the membrane
Fb Membrane Pretreatment No (used as received)
Fb Ferrocyanide Chemical Details Potassium hexacyanoferrate(II) trihydrate, K4Fe(CN)6 · 3H2O
Fb Ferrocyanide Purity 98.5
Fb Ferrocyanide Supplier Sigma Aldrich
Fb Ferricyanide Chemical Identity Potassium ferricyanide(III), K3Fe(CN)6
Fb Ferricyanide Purity 99.0
Fb Ferricyanide Supplier Sigma Aldrich
Fb Supporting Electrolyte Identity Potassium chloride, KCl
Fb Potassium Chloride Purity 99.0
Fb Potassium Chloride Supplier Sigma Aldrich
Fb Water Type Deionised
Fb Water Purification System Unknown
Fb Water Purification Details Unknown
Fb Water Resistivity 1.7
Fb Electrolyte Preparation Strategy Single stock batch used across repeats
Fb Electrolyte Batch Size 1000.0
Fb Electrolyte Storage Environment Dark (cupboard/covered)
Fb Electrolyte Storage Duration 312.0
Fb Electrolyte Volume Measurement Method Volumetric
Fb Reagent Purity Used No
Fb Water Ph Measured Yes
Fb Electrolyte Ph Measured Yes
Fb Electrode Cutting Method Manual cutting using ruler and razor/scalpel
Fb Potentiostat Usage Single instrument for all tests
Fb Potentiostat Manufacturer Cycling Biologic
Fb Potentiostat Model Cycling VMP3
Fb Potentiostat Manufacturer Polarisation Biologic
Fb Potentiostat Model Polarisation VMP3
Fb Potentiostat Manufacturer Impedance Biologic
Fb Potentiostat Model Impedance VMP3
Fb Potentiostat Calibration Frequency Calibrated only when issues arise
Fb Potentiostat Calibration Method Dummy cell (manufacturer supplied)
Fb Connection Method Crocodile/alligator clips
Fb Electrical Connection Scheme 2-point (4-wire)
Fb Potentiostat Cable Length <1 m
Fb Potentiostat Cable Type Manufacturer cable with third-party extension
Fb Potentiostat Cable Shielding Mixed shielding
Fb Number Of Pumps Single (including dual head)
Fb Pump Type Peristaltic
Fb Pump Manufacturer Heidolph
Fb Pump Model Hei-FLOW Value 01
Fb Reservoir Material Glass (borosilicate)
Fb Reservoir Type Duran/Schott bottle (GL bottle)
Fb Reservoir Volume 110.0
Fb Electrolyte Volume Used 100
Fb Impedance Reservoir Config Single reservoir
Fb Polarisation Reservoir Config Single reservoir
Fb Temperature Control Ambient (not controlled)
Fb Laboratory Temperature Not recorded
Fb Pump Flow Rate Calibrated Yes
Fb Calibration With Cell No
Fb Calibration Fluid Water
Fb Pump Recalibrated Yes
Fb Pump Calibration Method Manual gravimetric
Fb Leak Test Performed No
Fb Break In Performed Yes
Fb Break In Duration 5.0
Fb Break In Flow Rate 25
Fb Cell Assembly Issues No
Fb Additional Experiments No
Fb Electrolyte Leakage Reported No
Fb Typical Group Practice Leaks Tolerate minor leaks but document/report
Fb Electrolyte Stirring Yes
Fb Reservoir Stirring Method Magnetic stir bar
Fb Stirring Rate 100–200 RPM
Fb Electrolyte Sparging Yes
Fb Sparging Gas Argon
Fb Gas Humidification Humidified
Fb Sparging Application Pre-sparge then headspace blanket
Fb Sparging Gas Flow Rate Not recorded
Fb Polarisation Beyond Limits No
Fb Impedance Control Mode Potentiostatic (PEIS)
Fb Consent Public Display Yes